LSM Technologies
Also another critical condition to avoid is Co2 Concentrations in the Cabin which can contribute to Fatigue and cause Micro- sleeps

As another enhancement to the RESPA PFP Quality Cabin Air System Technology is our In- Cabin Pressure Sensor / Monitor / Warning Unit (Manometer).

Sy- Klone is one of the leading manufacturers and developers of Pre- cleaner Technology for Engines and the RESPA SD for HVAC Precleaner + Filtration +Pressuriser Technology (PFP).

The RESPA HVAC (PFP) Technology is the first in the world for Active Pre- cleaning air utilised in HVAC Systems on mobile and stationary plant / equipment.

Also another critical condition to avoid is Co2 Concentrations in the Cabin which can contribute to Fatigue and cause Micro- sleeps.

Our In- Cabin Pressure Sensor Unit can be set between 0- 200 pascals and will provide the Operator with a LED reading of the pressure within the Cabin. If the Cabin pressure drops below the Alarm set- point then this indicates:

  • If the cabin is properly sealed: If positive pressure is not maintained within the Cabin then contaminants can enter exposing the Operator to harmful airborne debris.
  • When to replace the RESPA fresh Air Filter Element?: If the cabin is properly sealed and the Pressure Sensor / Monitor still indicates reduced pressure, it is time to replace the Filter Element or Co2 concentration may occur.

Some other features of the ICPSensor are:

  • Pressure Sensing: Can be set for a pressure range between 0-200 pascal. 
  • Low Pressure Signal Alarm: Visual + Audible Alarm- Audible Alarms have three levels or can be turned- off.
  • Silence Alarm: a Silence Alarm button is provided.
  • LED Read Out: Provides a constant LED read- out of the Cabin Pressure.
  • No False Alarms: Allows for 10 seconds before alarming to allow for Doors  / Windows can be opened / shut.
  • Low voltage Output Signal: Allows for external monitoring / alarm or interfacing to telemetry of Cabin Pressure (20 pascal increments).
  • Robust, multi voltage input (12-36 VDC) and is simple / quick to install.

Please refer to the below product literature / installation guide for our In- Cabin Pressure Sensor / Monitor Unit.

If you require further information. please contact us. 


New Sensors monitors Cabin Pressure + Avoids Co2 Concentration in Fixed + Mobile Plant Cabins

Printable PDF

Download this news item as a printable PDF file.

This website and its contents © LSM Technologies Pty Ltd. All rights reserved.